Mid-size hard coat rectifier delivers 150 A at 160 V on a mid-size hard coat line. Each load carries a moderate surface area. A medium film builds in about 45 minutes at a moderate current density. Because the cabinet uses ducted air, it holds full current at a 40°C shop floor. No chiller loop is needed. Mid-size hard coat rectifier voltage headroom reaches 160 V. A batch that drifts past 70 V late in the cycle therefore still finishes on time. Operators set ramp time to 30 seconds. That ramp avoids the current spike which marks thin sections. Mid-size hard coat rectifier also sends fan and heatsink data over RS485. Maintenance then sees a rising trend before a trip.
Cooling: Ducted forced air | Application: Mid-size hard coat production | Interface: RS485 | Ripple: ≤2%
Hard coat shops run wear-resistant films on mixed aluminium loads. In addition, a typical batch draws 150 A at a moderate current density. Ducted air carries heat out through a wall vent. The line therefore runs in a workshop that never installed a water chiller.
Job shops that hard coat mixed parts also fit this model. Film targets range from light to medium thickness, and the 160 V ceiling covers both ends. Moreover, the 30 second ramp protects thin sections that would burn at full current.
| Rated output | 150 A / 160 V |
|---|---|
| Output mode | DC, constant current or constant voltage |
| Cooling | Ducted forced air, high-static fans |
| Input power | 380 V three phase, 50/60 Hz |
| Regulation | better than ±1% at rated load |
| Ripple | under 2% at rated load |
| Ramp | 0-60 seconds, programmable |
| Interface | RS485 |
| Protections | Over-current, over-voltage, over-temperature, airflow fault |
| Enclosure | Steel cabinet, wall vent kit supplied |
We can provide:
Our offer carries a twelve-month guarantee and an expected working life above ten years. First, regulation runs either in constant-current or constant-voltage mode. Then a soft-start ramp lifts current or voltage along a chosen slope. The clock timer closes a fixed hard-coat run, and several set-points can step through a scheduled film build. In addition, an RS485 link hands shift records to the quality log; automatic polarity reversal and minute-resolution timing are fitted throughout. Finally, tell us your bath layout for a tailored build.
Related Models:
Need less power? View the 20A 50V compact air-cooled anodizing rectifier.
Need more current? Check the 200A 200V high-voltage hard anodizing rectifier.
Need lower voltage? View the 2000A 60V large bath hard anodizing rectifier.
A: Products with the same nominal specifications often serve different industries, and they may carry different detailed parameter requirements. These differences directly affect production costs and technical solutions, so final prices will vary accordingly. For this reason, we recommend you contact us directly to receive a precise and tailored quotation.
A: We assign specialized consultants to support each industry sector. If you need further information, simply reach out to us. After we confirm your request, we will immediately send you the full technical datasheets and product images you need.
A: We focus on custom non-standard industrial power supplies, so we can fully adjust output current and voltage to match your exact needs. The products shown on our website only represent part of our actual range, as we do not list every model online. If you cannot find your desired specifications, please contact us directly. We will work with you to confirm your exact requirements, or we can guide you to select the most suitable parameters based on your industry standards. We will provide complete technical specifications and dimension drawings so you can fully understand the product.