High-voltage hard anodizing rectifier pushes 200 A to 200 V for thick hard coat work. Some materials grow oxide slowly, and bath voltage climbs past 90 V before the cycle ends. Because the ceiling sits at 200 V, the current loop keeps its setpoint. It does not fold back near the top of the ramp. High-voltage hard anodizing rectifier uses ducted air with a high-static fan. That airflow moves enough heat at 200 A on a 40°C floor. Ramp and multi-segment control let an operator step voltage at 60 V and 90 V. The log stores both stages. High-voltage hard anodizing rectifier also monitors heatsink temperature per phase. A blocked duct therefore shows up as a warning before a trip.
Cooling: Ducted forced air | Application: Thick hard coat film | Interface: RS485 | Ripple: ≤2%
Thick-film hard coat lines run parts that need a deep oxide layer. The voltage curve keeps rising as the film thickens. A 200 V ceiling lets the cycle finish at the target thickness. Any smaller supply would stop at its own limit.
Wear-resistant work also calls for multi-stage voltage steps. Those steps keep the coating dense, and the RS485 log supports the process file. As a result, the qualification report cites measured voltage rather than a nominal figure.
| Rated output | 200 A / 200 V |
|---|---|
| Output mode | DC with multi-stage voltage steps |
| Cooling | Ducted forced air, high-static fans |
| Input power | 380 V three phase, 50/60 Hz |
| Regulation | better than ±1% up to 200 V |
| Ripple | under 2% at rated load |
| Voltage steps | up to 6 segments per recipe |
| Interface | RS485 |
| Protections | Over-current, over-voltage, over-temperature, airflow fault |
| Enclosure | Steel cabinet, top duct flange |
We can provide:
one-year warranty cover with a service life above ten years. Constant current and constant voltage modes both run up to the full 200 V. A programmable ramp shapes current or voltage at start. Timed operation mode ends the cycle without an operator. Moreover, the multi-segment function steps the level at up to six points, and the RS485 interface carries the stage log to quality records. Automatic polarity reversal and minute-level timing are built in, so customization is available on request.
Related Models:
Need less power? View the 150A 160V mid-size hard coat rectifier.
Need lower voltage? View the 200A 100V twin-output hard anodizing rectifier.
Need lower voltage? View the 1000A 100V thick film hard anodizing rectifier.
A: Products with the same nominal specifications often serve different industries, and they may carry different detailed parameter requirements. These differences directly affect production costs and technical solutions, so final prices will vary accordingly. For this reason, we recommend you contact us directly to receive a precise and tailored quotation.
A: We assign specialized consultants to support each industry sector. If you need further information, simply reach out to us. After we confirm your request, we will immediately send you the full technical datasheets and product images you need.
A: We focus on custom non-standard industrial power supplies, so we can fully adjust output current and voltage to match your exact needs. The products shown on our website only represent part of our actual range, as we do not list every model online. If you cannot find your desired specifications, please contact us directly. We will work with you to confirm your exact requirements, or we can guide you to select the most suitable parameters based on your industry standards. We will provide complete technical specifications and dimension drawings so you can fully understand the product.