Aerospace chromic acid rectifier runs 500 A at 50 V on chromic baths that build thin films. Likewise, chromic acid mist is aggressive on copper parts. Coated busbars, coated studs and a sealed interior therefore keep this set alive in a mist-heavy room. The film stays thin, so ripple and stability matter more than raw voltage. This cabinet holds both inside a tight band. Aerospace chromic acid rectifier holds regulation within ±1% while the bath sits at 32-35°C. Water cooling carries heat out of the cabinet, so the set keeps its rating in a closed room. Aerospace chromic acid rectifier also logs each lot against a batch number. Moreover, that log feeds the traceability file.
Cooling: Water cooled | Application: Chromic acid thin film | Interface: RS485 | Ripple: ≤2%
Surface treatment shops coat loads in a chromic bath before primer. The film measures a few microns, so the run lasts 30 to 40 minutes at 40 V. Next, a full rack draws about 500 A. Parts leave the bath with a pale grey surface that holds paint and resists corrosion.
Repair stations also use chromic acid for rework on ageing equipment. Similarly, small lots run beside large ones, and the current loop keeps both inside the same tolerance. Moreover, the coated internals cut the maintenance hours that acid mist usually adds.
| Rated output | 500 A / 50 V |
|---|---|
| Output mode | DC, constant current or constant voltage |
| Cooling | Water cooled, acid-mist-sealed air path |
| Input power | 380 V three phase, 50/60 Hz |
| Regulation | better than ±1% at rated load |
| Ripple | under 2% at rated load |
| Bath temperature | rated for 32-35°C chromic baths |
| Interface | RS485 |
| Protections | Over-current, over-voltage, low flow, over-temperature |
| Enclosure | Sealed steel cabinet with coated copper busbars |
We can provide:
a one-year warranty and a service life above ten years. Constant current and constant voltage control both come with the cabinet. Furthermore, the programmable ramp avoids a hard start on a thin-film bath. Timed operation mode suits a 30 to 40 minute chromic cycle. Furthermore, the multi-segment function varies the level if your process needs a step. In addition, the RS485 interface carries the lot log into quality records. Besides, automatic polarity reversal and minute-level timing are fitted. Ask us about customization.
Related Models:
Need higher voltage? Check the 200A 200V high-voltage hard anodizing rectifier.
Need lower voltage? View the 1000A 24V high-current sulfuric anodizing rectifier.
Need more current? Check the 1000A 100V thick film hard anodizing rectifier.
A: Products with the same nominal specifications often serve different industries, and they may carry different detailed parameter requirements. These differences directly affect production costs and technical solutions, so final prices will vary accordingly. For this reason, we recommend you contact us directly to receive a precise and tailored quotation.
A: We assign specialized consultants to support each industry sector. If you need further information, simply reach out to us. After we confirm your request, we will immediately send you the full technical datasheets and product images you need.
A: We focus on custom non-standard industrial power supplies, so we can fully adjust output current and voltage to match your exact needs. The products shown on our website only represent part of our actual range, as we do not list every model online. If you cannot find your desired specifications, please contact us directly. We will work with you to confirm your exact requirements, or we can guide you to select the most suitable parameters based on your industry standards. We will provide complete technical specifications and dimension drawings so you can fully understand the product.